The MINIWONE series consists of high-efficiency units of very compact design.
They are developed to meet the heating or cooling requirements of smaller systems.
In cooling mode, the controller operates the unit as a liquid chiller,
while in heating mode it operates as a heat pump.
MINIWONE units are intended for indoor installation.
Outdoor installation is possible with certain modifications.
The compressor is semi-hermetic reciprocating, controlled by a high-efficiency frequency inverter
that enables soft start and continuous speed variation for precise cooling/heating capacity control.
The evaporator and condenser are plate heat exchangers with advanced heat transfer characteristics
(SWEP AsyMatrix technology), ensuring maximum heat transfer efficiency and a significantly reduced refrigerant charge.
MINIWONE units can be designed for high-temperature heating.
High-temperature heat pumps use the natural refrigerant R600a to heat water up to 90 °C.
Each MINIWONE unit is factory tested and delivered pre-charged with refrigerant and oil.
Conformity assessment is carried out in accordance with the European Pressure Equipment Directive (PED) 2014/68/EU.
The unit complies with all safety and environmental requirements.
Number of refrigeration circuits*: 1
*Number of refrigeration circuits equals the number of compressors
Unit dimensions:
Length: 1660 mm
Width: 850 mm
Height: 1300 mm
GENERAL
Powder-coated galvanized steel housing, corrosion and weather resistant, standard color RAL 7035
Removable housing panels
Anti-vibration mounts
Compressor compartment located in a separate protective enclosure within the housing
Pipe insulation to prevent condensation
Safety strategy selection – permanent compressor compartment ventilation or refrigerant leak detector combined with ATEX fan
ELECTRICAL
Main power switch and phase monitoring relay
Electrical protection for all components
Advanced Siemens microprocessor controller supervising full unit operation
Electronic expansion valve for precise refrigerant flow control
Communication protocols: Modbus TCP/IP, Modbus RTU or BACnet IP
Dry contacts for alarms
Remote unit access
HYDRAULIC CIRCUIT
Copper pipes of the hydraulic circuit
Hydraulic connection via copper threaded connection
Air vent valve
Safety valve
Drain valve (for system filling and draining)
Flow switch
Thermal insulation of piping
GENERAL
Custom housing color
Low-noise version with additional sound insulation
ELECTRICAL
Cabinet lamp with socket
Electrical cabinet heater (250 W)
Remote monitoring (Siemens Cloud)
HYDRAULIC CIRCUIT
Shut-off valves
Primary-side circulation pump (cold side)
Primary-side circulation pump (hot side)
Self-regulating heating cables for frost protection